TaiLexi AI日本の判例・法令
通達厚生労働省医薬食品

平成22年9月29日事務連絡第十五改正日本薬局方の一部改正に係る英文版(グリセリン及び濃グリセリンに係る一部改正)について

医薬品、医療機器等の品質、有効性及び安全性の確保等に関する法律第4編 医薬食品 / 第1章 医薬食品 / 医薬品、医療機器等の品質、有効性及び安全性の確保等に関する法律
発出 平成22年9月29日 事務連絡

標記について、平成20年2月21日厚生労働省告示第32号により、第十五改正日本薬局方の一部改正をしたところですが、今般、別添のとおり英文版を作成しましたので御連絡いたします。

なお、当該英文版に対応する邦文版を参考として添付いたします。

別添

Glycerin

グリセリン

Change the Purity(11)to Purity(12)and add the following next to Purity(10)

Purity(11)Diethylene glycol and related substances-Weigh accurately about 5.88g of Glycerin,mix in methanol,add methanol to make exactly 100mL,and use this solution as the sample solution.Separately,weigh accurately about 0.1g of Diethylene glycol,mix in methanol,and add methanol to make exactly 100mL.Pipet 5mL of this solution,add methanol to make exactly 100mL,and use this solution as the standard solution.Perform the test with 1μL each of the sample solution and standard solution as directed under Gas Chromatography<2.02>according to the following conditions.Determine each peak area of the sample solution and standard solution by the automatic integration method,and determine the peak areas,AT and AS,of diethylene glycol in each solution.Calculate the amount of diethylene glycol by the following equation:not more than 0.1%.Calculate the amount of the related substances in the sample solution by the area percentage method:each amount of the related substances other than glycerin and diethylene glycol is not more than 0.1% and the total amount of peaks other than glycerin is not more than 1.0%.

Amount(%)of diethylene glycol=(WS/WT)×(AT/AS)×5/0.85

WS:Amount(g)of diethylene glycol

WT:Amount(g)of glycerin

Operating conditions-

Detector:A hydrogen flame-ionization detector.

Column:A fused-silica column 0.32mm in inside diameter and 30m in length,coated the inner surface with 14% cyanopropylphenyl/86% dimethylsilicon polymer for gas chromatography 1μm in thickness.

Column temperature:Inject at a constant temperature of about 100℃,raise at the ratio of 7.5℃ per minute to 220℃,and maintain at a constant temperature of about 220℃.

Injection port temperature:A constant temperature of about 220℃.

Detector temperature:A constant temperature of about 250℃.

Carrier gas:Helium

Flow rate:About 38cm per second.

Split ratio:1:20

Time span of measurement:About 3times as long as the retention time of glycerin,beginning after the solvent peak.

System suitability-

System performance:Weigh 0.05g of Diethylene glycol and Glycerin,and mix in 100mL of methanol.When the procedures is run with 1μL of this solution under the above operating conditions,diethylene glycol and glycerin are eluted in this order with the resolution between these peaks being not less than 7.0.

System repeatability:When the test is repeated 6times with 1μL of the standard solution under the above operating conditions,the relative standard deviation of the peak area of diethylene glycol is not more than 15%.

Concentrated Glycerin

濃グリセリン

Change the Purity(11)to Purity(12)and add the following next to Purity(10)

Purity(11)Diethylene glycol and related substances-Weigh accurately about 5g of Concentrated Glycerin,mix in methanol,add methanol to make exactly 100mL,and use this solution as the sample solution.Separately,weigh accurately about 0.1g of Diethylene glycol,mix in methanol,and add methanol to make exactly 100mL.Pipet 5mL of this solution,add methanol to make exactly 100mL,and use this solution as the standard solution.Perform the test with 1μL each of the sample solution and standard solution as directed under Gas Chromatography<2.02>according to the following conditions.Determine each peak area of the sample solution and standard solution by the automatic integration method,and determine the peak areas,AT and AS,of diethylene glycol in each solution.Calculate the amount of diethylene glycol by the following equation:not more than 0.1%.Calculate the amount of the related substances in the sample solution by the area percentage method:each amount of the related substances other than glycerin and diethylene glycol is not more than 0.1% and the total amount of peaks other than glycerin is not more than 1.0%.

Amount(%)of diethylene glycol=(WS/WT)×(AT/AS)×5

WS:Amount(g)of diethylene glycol

WT:Amount(g)of concentrated glycerin

Operating conditions-

Detector:A hydrogen flame-ionization detector.

Column:A fused-silica column 0.32mm in inside diameter and 30m in length,coated the inner surface with 14% cyanopropylphenyl/86% dimethylsilicon polymer for gas chromatography 1μm in thickness.

Column temperature:Inject at a constant temperature of about 100℃,raise at the ratio of 7.5℃ per minute to 220℃,and maintain at a constant temperature of about 220℃.

Injection port temperature:A constant temperature of about 220℃.

Detector temperature:A constant temperature of about 250℃.

Carrier gas:Helium

Flow rate:About 38cm per second.

Split ratio:1:20

Time span of measurement:About 3times as long as the retention time of glycerin,beginning after the solvent peak.

System suitability-

System performance:Weigh 0.05g of Diethylene glycol and Glycerin,and mix in 100mL of methanol.When the procedures is run with 1μL of this solution under the above operating conditions,diethylene glycol and glycerin are eluted in this order with the resolution between these peaks being not less than 7.0.

System repeatability:When the test is repeated 6times with 1μL of the standard solution under the above operating conditions,the relative standard deviation of the peak area of diethylene glycol is not more than 15%.

(参考)

グリセリン

第十五改正日本薬局方医薬品各条グリセリンの条純度試験の項中(11)を(12)とし、(10)の次に次のように加える。

(11)ジエチレングリコール及び類縁物質 本品約5.88gを精密に量り,メタノールに混和し,正確に100mLとし,試料溶液とする.別にジエチレングリコール約0.1gを精密に量り,メタノールに混和し,正確に100mLとする.この液5mLを正確に量り,メタノールを加えて正確に100mLとし,標準溶液とする.試料溶液及び標準溶液1μLずつを正確にとり,次の条件でガスクロマトグラフィー〈2.02〉により試験を行う.試料溶液及び標準溶液の各々のピーク面積を自動積分法により測定し,それぞれの液のジエチレングリコールのピーク面積AT及びASを求める.次式によりジエチレングリコールの量を求めるとき,0.1%以下である.また,試料溶液の各々のピーク面積を面積百分率法により求めるとき,グリセリン及びジエチレングリコール以外の個々のピークの量は0.1%以下であり,グリセリン以外のピークの合計量は1.0%以下である.

ジエチレングリコールの量(%)=(WS/WT)×(AT/AS)×5/0.85

WS:ジエチレングリコールの秤取量(g)

WT:本品の秤取量(g)

試験条件

検出器:水素炎イオン化検出器

カラム:内径0.32mm,長さ30mのフューズドシリカ管の内面にガスクロマトグラフィー用14%シアノプロピルフェニル―86%ジメチルシリコーンポリマーを厚さ1μmで被覆する.

カラム温度:100℃付近の一定温度で注入し,毎分7.5℃で220℃まで昇温し,220℃付近の一定温度で保持する.

注入口温度:220℃付近の一定温度

検出器温度:250℃付近の一定温度

キャリヤーガス:ヘリウム

流量:約38cm/秒

スプリット比:1:20

面積測定範囲:溶媒のピークの後からグリセリンの保持時間の約3倍の範囲

システムの適合性

システムの性能:ジエチレングリコール及びグリセリン0.05gずつをメタノール100mLに混和する.この液1μLにつき,上記の条件で操作するとき,ジエチレングリコール,グリセリンの順に溶出し,その分離度は7.0以上である.

システムの再現性:標準溶液1μLにつき,上記の条件で試験を6回繰り返すとき,ジエチレングリコールのピーク面積の相対標準偏差は15%以下である.

濃グリセリン

第十五改正日本薬局方医薬品各条濃グリセリンの条純度試験の項中(11)を(12)とし、(10)の次に次のように加える。

(11)ジエチレングリコール及び類縁物質 本品約5gを精密に量り,メタノールに混和し,正確に100mLとし,試料溶液とする.別にジエチレングリコール約0.1gを精密に量り,メタノールに混和し,正確に100mLとする.この液5mLを正確に量り,メタノールを加えて正確に100mLとし,標準溶液とする.試料溶液及び標準溶液1μLずつを正確にとり,次の条件でガスクロマトグラフィー〈2.02〉により試験を行う.試料溶液及び標準溶液の各々のピーク面積を自動積分法により測定し,それぞれの液のジエチレングリコールのピーク面積AT及びASを求める.次式によりジエチレングリコールの量を求めるとき,0.1%以下である.また,試料溶液の各々のピーク面積を面積百分率法により求めるとき,グリセリン及びジエチレングリコール以外の個々のピークの量は0.1%以下であり,グリセリン以外のピークの合計量は1.0%以下である.

ジエチレングリコールの量(%)=(WS/WT)×(AT/AS)×5

WS:ジエチレングリコールの秤取量(g)

WT:本品の秤取量(g)

試験条件

検出器:水素炎イオン化検出器

カラム:内径0.32mm,長さ30mのフューズドシリカ管の内面にガスクロマトグラフィー用14%シアノプロピルフェニル―86%ジメチルシリコーンポリマーを厚さ1μmで被覆する.

カラム温度:100℃付近の一定温度で注入し,毎分7.5℃で220℃まで昇温し,220℃付近の一定温度で保持する.

注入口温度:220℃付近の一定温度

検出器温度:250℃付近の一定温度

キャリヤーガス:ヘリウム

流量:約38cm/秒

スプリット比:1:20

面積測定範囲:溶媒のピークの後からグリセリンの保持時間の約3倍の範囲

システムの適合性

システムの性能:ジエチレングリコール及びグリセリン0.05gずつをメタノール100mLに混和する.この液1μLにつき,上記の条件で操作するとき,ジエチレングリコール,グリセリンの順に溶出し,その分離度は7.0以上である.

システムの再現性:標準溶液1μLにつき,上記の条件で試験を6回繰り返すとき,ジエチレングリコールのピーク面積の相対標準偏差は15%以下である.

この資料について AI に質問

出典:厚生労働省ホームページ「法令等データベースサービス」(https://www.mhlw.go.jp/web/t_doc?dataId=00tb6479&dataType=1&pageNo=1)を加工して作成(加工:TaiLexi AI)
通達・ガイドライン等は行政機関の解釈・運用の考え方を示すもので、国民や裁判所を直接拘束するものではありません。